Three Precision Problems Should Be Paid Attention To In The Use Of Metering Pump

Feb 21, 2018

Leave a message

1) steady-state accuracy of metering pump: rated flow rate of plus or minus 2%. If the measurement pump is measured with 100% stroke flow rate of 1000L/h, the steady-state accuracy allowable deviation is plus or minus 2%*1000= plus or minus 20 L/h. Steady state precision refers to the amount of flow deviation obtained at different time points at different time points to calibrate the pump flow at different time points without making any adjustments and changes.

2) linear precision: the rated flow rate of plus or minus 3 percent. If the measurement pump is measured with 100% stroke flow rate of 1000L/h, then the linear accuracy allowable deviation is plus or minus 3%*1000= plus or minus 30L/h. Linear precision refers to the deviation between the measured flow rate and the best fitting value of the measured flow rate in the range of 10%~100% of the measuring pump and the flow calibration of the different stroke points evenly.

3) repeat precision: the rated flow rate of + or + 3%, if the measurement pump is measured with 100% stroke flow rate of 1000L/h, then the repeat accuracy allows deviation to be plus or minus 3%*1000= plus or minus 30L/h. Repeatability refers to the metering pump within the range of 10% ~ 100%, choose a trip point for flow calibration, and change the stroke of the pump to run after a period of time, once again return to the original schedule point for flow calibration, the resulting flow deviation.